# **Medium-Voltage UPS Product Overview**
## **1. Product Overview**
The medium-voltage UPS is a high-capacity power protection system designed for large industrial facilities and mission-critical loads. Operating at voltage levels from **6.6 kV to 24 kV**, it ensures continuous, uninterruptible power and prevents production downtime caused by grid disturbances such as voltage dips, sags, flicker, and short interruptions.
Built on the advanced **ZISC (Impedance-Isolated Static Converter) architecture**, the system delivers exceptional reliability, high efficiency, and ultra-fast switching performance. It is an ideal continuity-of-power solution for modern factories, power-sensitive industries, and large-scale infrastructure.
---
## **2. Key Features**
### **① Ultra-High Efficiency — Up to 98%**
* Maintains **98% efficiency** across the 50%–100% load range.
* Significant energy savings compared with traditional rotary UPS systems.
* Reduces PUE and overall operational costs, especially in large-load environments.
### **② Megawatt-Level Scalability — 2.25 to 22.5 MW**
* Single-unit rating: **2250 kW / 2250 kVA**
* Supports up to **10 units in hard parallel**, allowing a total output of **22.5 MW**.
* Suitable for steel plants, mining sites, data centers, airports, and other centralized power distribution setups.
### **③ Ultimate Reliability — ZISC Topology + MV-Side Protection**
* ZISC-enabled line-interactive topology, engineered specifically for MV UPS.
* High fault-clearing capability with direct medium-voltage protection.
* Lower current, reduced loss, and more stable architecture.
* Hot-swappable PEBB power modules, reducing MTTR to **under 15 minutes**.
### **④ Long Battery Life — Li-Ion Technology with 15-Year Design Life**
* ABB-certified lithium-ion battery system.
* Customizable backup time from **15 seconds to 15 minutes**.
* Minimal maintenance requirements.
* Supports **Demand Response** for peak shaving and energy optimization.
### **⑤ Long Service Life — 15-Year System Design**
Engineered with a 15-year design life, far exceeding conventional UPS systems and reducing long-term maintenance costs.
### **⑥ Digital Monitoring — 10” Touch Display + Remote Diagnostics**
* 10-inch full-color touchscreen.
* Waveform capture and event logging.
* Trend analysis and performance monitoring.
* Remote communication via **Ethernet / Modbus TCP**.
* Compatible with ABB Ability™ cloud-based monitoring platform.
---
## **3. Working Principle**
The medium-voltage UPS is installed directly on the MV distribution bus. Using the ZISC topology, it continuously monitors the input power quality in real time.
When disturbances such as:
* Voltage dips
* Flicker
* Short interruptions
* Frequency anomalies
occur, the system **switches to internal energy storage within milliseconds**, ensuring downstream critical loads receive a clean, stable sine-wave power supply with **zero interruption**.
---
## **4. Typical Applications**
The MV UPS is designed for industries where continuous operation is essential and power outages cause substantial losses:
### **🏭 Steel & Metallurgy**
Protects EAFs, CCMs, drives, and plant-wide control systems from sudden voltage dips.
### **⚙️ Large Mines & Smelting Plants**
Ensures continuous operation of hoists, compressors, ventilation systems, and mineral processing equipment.
### **🖥 Data Centers**
Provides high-reliability medium-voltage power protection and reduces PUE; replaces large LV UPS clusters.
### **⛽ Oil & Gas**
Supports pump stations, central control rooms, SCADA, and mission-critical communication systems.
### **🏥 Hospitals / Airports / Metro Systems**
Safeguards essential loads such as signaling systems, dispatch centers, elevators, and operating theaters.
---
## **5. Technical Specifications**
| Item | Specification |
| ------------------- | ------------------------------- |
| Rated Voltage | 6.6 / 10 / 11 / 13.8 / 20–22 kV |
| Single Unit Power | 2250 kW |
| Parallel Capability | Up to 10 units (22.5 MW) |
| Efficiency | 98% (50–100% load) |
| Topology | ZISC line-interactive |
| Battery Type | Li-ion |
| Backup Time | 15 seconds – 15 minutes |
| Display | 10" touchscreen |
| Communication | Ethernet / Modbus TCP |
| Design Life | 15 years |
---
## **6. Customer Value Proposition**
✔ **Zero power interruptions**, preventing costly production losses
(steel/mine downtime can exceed hundreds of thousands of USD per event)
✔ **Lowest long-term operating cost**
98% efficiency + reduced distribution line losses through MV-level protection.
✔ **Lower CAPEX**
MV-side protection eliminates the need for large LV UPS banks.
✔ **Extended battery life & minimal maintenance**
Ideal for remote, unmanned, and large industrial sites.
✔ **Reliable protection for critical IT loads**
Ensures stable, clean power for servers, automation systems, and Tier III/IV data centers.
✔ **Improved stability during generator transitions**
Acts as a highly stable buffer system.
If you need to purchase related products, feel free to contact us!